![]() |
International Journal of Scientific Research and Engineering Development( International Peer Reviewed Open Access Journal ) ISSN [ Online ] : 2581 - 7175 |

Complementary Seismic Performance of Hybrid Damping Systems in Frames, Wall-Frames and Isolated Bridges under Far-Field, Near-Fault and Long-Duration Ground Motions
📑 Paper Information
| 📑 Paper Title | Complementary Seismic Performance of Hybrid Damping Systems in Frames, Wall-Frames and Isolated Bridges under Far-Field, Near-Fault and Long-Duration Ground Motions |
| 👤 Authors | Vinod Tiwari, Dr.Shelar Abhay Baburao, Dr. Manoj Sharma |
| 📘 Published Issue | Volume 9 Issue 6 |
| 📅 Year of Publication | 2026 |
| 🆔 Unique Identification Number | IJSRED-V9I6P80 |
| 🌐 DOI | In-Process |
📝 Abstract
Hybrid damping systems combine mechanically unlike energy-dissipation paths so that each controls a seismic demand the other leaves uncontrolled, yet most published studies compare a hybrid only with the unequipped structure and therefore cannot show that the second path adds anything. This paper evaluates the complementary action of four hybrid assemblies—a parallel viscous–metallic (VM) brace, a friction–viscoelastic (FV) stack, a self-centring (SC) brace with a yielding fuse, and an isolation-plus-damper plane—by comparing each against its own single-mechanism parents with the first-path coefficient held constant. Nonlinear models of four prototypes designed to IS 1893 Zone IV (an eight-storey RC frame, an eight-storey steel frame, a twenty-storey RC wall-frame and a three-span isolated highway bridge) were analysed in OpenSees under separate far-field, near-fault pulse and long-duration record suites, followed by parametric, property-bound, incremental dynamic and second-shock analyses. On the RC frame the VM hybrid at a force-share of 0.70 reduced far-field median peak drift from 1.85 % to 0.92 % (24 % below the better parent) and pulse residual drift from 0.85 % to 0.38 %, while the SC brace reduced residual drift to 0.12 %. Complementarity was class-dependent and index-specific: base shear rose for every equipped frame, and the hybrid benefit appeared as coupling-beam travel on the wall-frame and as bearing stroke (−26 %) and residual offset (−66 %) on the bridge. Force-share, engagement threshold and placement were found to be non-interchangeable design variables. A stepwise design procedure is proposed.
📝 How to Cite
Vinod Tiwari, Dr.Shelar Abhay Baburao, Dr. Manoj Sharma, "Complementary Seismic Performance of Hybrid Damping Systems in Frames, Wall-Frames and Isolated Bridges under Far-Field, Near-Fault and Long-Duration Ground Motions" International Journal of Scientific Research and Engineering Development, V9(6): Page(585-591) November - December 2026. ISSN: 2581-7175. www.ijsred.com. Published by Scientific and Academic Research Publishing.
📘 Other Details
